Determine the instrument blank.

a. Login a minimum of 3 Blank replicates.

b. Press the Analyze button on the instrument screen. After a short delay, the loading head slide-block will open.

c. Press the Analyze button on the instrument screen again, the loading head slide-block will close and the lower electrode will open.

d. Clean the upper and lower electrode manually, or, if applicable, remove thecrucible and press the analyze button to clean with the automatic cleaner.

e. Firmly place a graphite crucible on the lower electrode tip.

f. Press the Analyze button on the instrument screen, the lower electrode will close and the analysis sequence will start and endautomatically.

g. Repeat steps 2b through 2f a minimum of three times.

h. Set the blank following the procedure outlined in the operator's instruction manual.


用户友好界面的Cornerstone™ 软件。分析仪厂家报价

分析仪厂家报价,分析仪

Instrument Highlights and Features


Features and Benefits

LED light ring illuminates the furnace area

Choice of either argon or helium carrier gas

Novel electrode design increases heat transfer efficiency for increased stability

Non-touch interface systems are also available

User-friendly brand software



High-Performance Detector Design

Thermostatic construction provides increased protection from ambient temperature fluctuations

Optimized emitter control and detection circuitryimproves the IR cell lifetime and long-term stability,

resulting in superior accuracy and precision

Infrared detection for the determination of oxygen, thermoconductivity detection for the determination

of nitrogen




北京美国LECO氧氮氢分析仪价格长寿命的红外发射光源和无漂移的电路设计保证检测器的长期稳定性。

分析仪厂家报价,分析仪

ONH836系列:氧氮氢分析仪(熔融法)

力可ONH836系列仪器采用惰性熔融法,提供各种无机材料、钢铁、有色金属、硬质合金、陶瓷材料中宽范围的氧氮氢同时分析。

ONH836系列仪器通过***采纳客户的反馈意见和创新设计,力可***仪器采用触摸屏技术和在线软件平台,增强了仪器的可操作性、降低了分析成本、节省实验室桌面空间。


用户友好界面的Cornerstone™ 软件

力可**的Cornerstone 氧氮氧分析软件采用触摸屏界面使用户可完整的达到分析控制、方法设定、在线诊断、数据报告。Cornerstone  氧氮氧分析软件允许用户在单一分析界面中完成日常的所有工作,快速而且简单易用。力可创新的批次和重复样品数据分组功能极大简化了样品结果输出和结果标准偏差的自动计算,减少了繁琐的额外数据处理。


Procedure – Powder/Chip Samples

Instrument calibration/drift correction.

Calibrate/drift following the procedure outlined in the operator's instruction manual.


Analyze Samples.

Login Sample with the appropriate number of reps.

Weigh approximately *** grams of appropriately prepared sample into a *** Nickel Capsule, enter mass and sample identification into appropriate rep fields. If applicable, place the nickel capsule in the

appropriate autoloader position.

Repeat steps 3c through 3i for sample analysis.


Cornerstone氧氮氧分析软件允许用户在单一分析界面中完成日常的所有工作,快速而且简单易用。

分析仪厂家报价,分析仪

Procedure - Solid Samples

Prepare the instrument as outlined in the operator's instruction manual.


Determine the instrument blank.

Login a minimum of 3 Blank replicates.

Press the Analyze button on the instrument screen. After a short delay, the loading head slide-block will open. Place a 502-344 Nickel Basket into the loading head.

Note: samples using automation should be placed in the appropriate autoloader position before starting the

analysis sequence. Once the sequence has started, the automatic analysis will start and end automatically.


双直流风扇保证持续冷却,不受电压波动的影响。美国分析仪优惠价格

试样加载过程中完全密闭,消除大气的中可能带来的杂质的污染。分析仪厂家报价

Procedure – Powder/Chip Samples

Instrument calibration/drift correction.

Add approximately 0.05 g of *** Graphite Powder to a***Graphite Crucible.

Firmly place the crucible on the lower electrode tip or appropriate autoloader position.

Press the Analyze button on the instrument screen,the lower electrode will close and the analysis sequence will start and end automatically.

Repeat steps 3b through 3i a minimum of three times for each calibration/drift standard used.